LAUNCH X431 O2-2 Scopebox Oscilloscope (4 Channels) Analizador Digital Scopebox Tester USB Port Works with X431 PAD VII, PAD V, PAD III

Marken: Launch X431 Art.-Nr.SO737 Auf Lager. Geschichte 1 verkauft.

Sofort Kaufen: 519.00
V2024.3 Super MB Pro M6+ DoIP, View More

2024 Top ECU Tools

Feel free to contact us for better price:
Whatsapp: +86 181 5015 2701
Email: sales@autoobd.de
Versand:
Kostenloser Versand Express Versand ServiceExpress Versand Service Gesch?tzte Lieferzeit von China: 5-7 Werktage. Siehe Einzelheiten »
Gewicht:
4.9KG
Paket:
44cm*38cm*14cm ( Zoll: 17.32*14.96*5.51 )
Rückkehr:
Rückkehr für Rückerstattung innerhalb von 7 Tagen bezahlt Käufer shipping. zurückkehren »

Produktbeschreibung

  1. Electrical analyzer (oscilloscope)
  2. Analyzes data to resolve complex electrical faults for launch PAD V / PAD VII
  3. Versatile and easy-to-use add-on module that can detect high-level faults in various electrical components, such as sensors, actuators and circuits.

LAUNCH X431 O2-2 Scopebox Oscilloscope (4 Channels) Analizador Digital Scopebox Tester

Launch O2-2 Scope Box allows the user to capture a particular waveform which makes the process 70% more efficient as compared to other scopes. It features the ability to record and playback high-resolution waveform data for future analysis. Its ability to input names and characters directly by clicking on the virtual keyboard streamlines the process and contributes to 90% of efficiency improvement.

Product Highlights:

4 channels
Bandwidth 100MHz
Auto configuration
Save waveforms with one click
Cursor measurement
One-click preset waveform parameter settings
Demo mode
Online help
Waveform math operations
23 automatic measurements

Product Features:

One key enable function

Access to 23 variants of automatic measurements that are displayed on one screen for an easy switch.

Buffer memory up to 50M.

Use the zoom in/out feature to review precise details

Customizable personal system settings that can be saved as configuration files for viewing

Self-calibration function allows optimization of the oscilloscope signal path for maximum measurement accuracy.

Magnifies waveform math operations, such as addition, subtraction, multiplication and FFT function for high level waveform analysis.

Multiple automotive tests that include circuits, sensors, actuators, ignition tests and more.

Multi language user interface.

USB Sync Data Transfer to external devices such as laptop, tablet, etc....

Product Functions:

Supports multiple vehicle preset project tests
Supports a variety of automotive preset project tests, such as circuits, sensors, actuators, ignition tests, communication tests and combination tests, and presets various parameters and specific connection methods for each test.

23 automatic measurement settings
23 automatic measurement settings are displayed on one screen, which is clear at a glance and can be clicked with a light touch. It supports one-click clearing, eliminating the tediousness of turning pages and searching multiple times, making automatic measurement easy to use and convenient.

Quick trigger source switching
Supports edge, pulse and other triggers. Simple and intuitive trigger settings and fast trigger source switching methods make the most difficult part of oscilloscope application extremely easy.

Quickly create waveform preset parameters with one click
When testing waveforms, you can save the existing settings on the current interface as waveform preset parameters with one click. When testing similar waveforms later, you can directly load the preset parameters without repeated settings.

Quickly save waveforms with one click
Quickly save the waveform currently displayed on the screen with one click and automatically save it in the specified format. It can be directly used as a reference channel waveform for display later.

Convenient cursor operation
Turn on the horizontal and vertical cursors with one click respectively. Each cursor can be dragged independently, and cursor tracking is also directly implemented through simple highlight touches, improving overall efficiency by more than 80%.

Support cursor/phase ruler changes accordingly
When the waveform is zoomed in/out, the cursor and phase scale can change accordingly, keeping the measurement range unchanged.

Supports 2-point touch, the waveform can be zoomed in or out vertically or horizontally
Drag horizontally or vertically with 2 points to zoom in or out the waveform horizontally or vertically.

Support demonstration function
Preset sine waveforms to demonstrate common functions without connecting an oscilloscope.

Supports waveform math operations
Supports addition, subtraction, multiplication and division calculations of two channel waveforms, in addition to fast Fourier transform.

Detailed Comparison Between Launch O2-2 Scope Box and Launch O2-1 Scope Box
Model O2-1 O2-2
Channel 4 4
Bandwith 100MHz 100MHz
Rise Time ≤3.5ns(typical) ≤3.5ns
Maximum sampling rate 1Gbps(for four channels) 1Gbps
Input resistance 1MΩ±1.5% 1MΩ±1.5%
Storage depth 50M 10M
Number of sampling bits 8bit 8bit
vertical accuracy 3% 3%
Vertical gear 5mV~10V 5mV~10V
Inverting Support Support
Channel coupled DC, AC DC, AC
Time base gear 5ns~1ks  1ns-1ks
Time base accuracy 20ppm 20ppm
Sampling mode Normal Normal
CANBus decoding CAN, LIN CAN, LIN
Trigger type Edge, Pulse width Edge, Pulse width
Trigger mode Normal, Auto and Single SEQ Normal, Auto and Single SEQ
Trigger coupling DC, Noise rejection DC, Noise rejection
Math Double waveFFT Double waveFFT
Display YT、Zoom、Roll YT、Zoom、Roll
Roll mode 200ms/div~1000s/div 200ms/div~1000s/div
Auto configuration Support Support
Auto measurement 23 23
Cursor Horizontal cursor, Vertical cursor Horizontal cursor, Vertical cursor
Powered by USB port, DC IN port USB port, DC IN port
Data transmission method USB USB
Vehicle configuration options Circuits, sensor, actuators, ignition Circuits, sensor, actuators, ignition
Operating temperature 0℃~50℃ 0℃~50℃
Power supply range USB:5V/1A
DC:12V/24V
USB:5V/1A
DC:12V/24V
Compatibility Different tablet resolutions require different APPs One APP can be compatible with multiple tablet resolutions
Multi-touch gestures No Supports 2-point touch, the waveform can be zoomed in or out vertically or horizontally
Vehicle configuration No Each test project can support online help documentation (help documentation will be compiled according to needs later)
Firmware upgrade Manual upgrade Support online upgrade
Trigger Waveform observation cannot be expanded during normal trigger waiting. Can be used normally during normal trigger waiting.
Demo function No Yes
Split-screen No Yes
Sampling rate Single channel 1G/s, more than 2 channels only 250M/s Single channel 1G/s, 2 channels 500M/s, multiple channels 250M/s
Start time 2-3S about 16s
Power consumption about 6W about 7.5W
 
How to Connect the Cables?

Different application scenarios require different connection methods (no matter which application scenario, the following connections are required):

First, power the oscilloscope box through the double-clip power cable: Connect one end of the double-clip power cable to the power interface of the oscilloscope box, and the other end to the vehicle battery to draw power (red is connected to the positive pole, black is connected to the negative pole).

Note: * PADVII series tablets support USB power supply.

2. Connect the Type B terminal of the USB cable to the Type B interface of the oscilloscope, and connect the other end to the USB interface of the diagnostic device.

Package Includes:

1pc x Launch O2-2 main unit
4pcs x HT 30 test lines
1pc x HT25 secondary ignition pick-up line
1pc x battery clip cable
1pc x USB cable
2pcs x HT201 attenuator
20pcs x piercing needles
2 pairs x multimeter probes
2 pairs x crocodile clips
5pcs x colored 4 female probes
4pcs x clipper fuses(5*20mm)
2pcs x screw head
1pc x user manual
1pc x color label
1pc x packing list

 

Die Bearbeitungszeit beträgt 48 Stunden. Wenn es ein Wochenende ist, wird die kompatible Zeit verzögert.

Lieferzeit:


Wenn auf Lager in EU / Czech / Amazon / UK, 2-5 Werktage in die EU / UK, keine Mehrwertsteuer.

1. Pfosten, 10-17 Arbeitstage, keine Zoll meist. Für Deutschland und Großbritannien verwenden wir eine neue Postfirma, deren Zustellung nur 6-7 Werktage dauert.

2. YANWEN Express, 7-10 Werktag, ohne Zoll.

3. DHL: 5-7 Werktag, mit Zoll. Zoll hat die Pflicht des Kunden, aber wir schreiben als Standardwert mit niedrigem Wert, um Zollgebühren in Ihrem Land zu sparen. Wenn Sie Zollanforderungen benötigen, schreiben Sie uns bitte, wenn Sie die Bestellung aufgeben.

Finden unsere Web auf eurer Telefon:

m.Autoobd.de QC code

Für Fragen, kontaktieren Sie uns bitte unter:


Telefon: +86 187 5090 6153

Whatsapp: +1 209 917 8434

Email: sales@AutoOBD.de